Item 95652 For technical questions, please call 1-888-866-5797. Page 2
Specifications
AC Amps
Ranges: 200/1000A
Resolution: 100mA/1A
Accuracy: ± 2% rdg +5d @ 50-60 Hz (up to 800A)
± 3% rdg +5d @ 50-60 Hz (above 800A)
Overload Protection: 1200A within 60 seconds
AC Voltage
Range: 750V
Resolution: 1V
Accuracy: ± 1% rdg +4d @ 50-500 Hz
Input Impedance: 9 MΩ
Overload Protection: 750V AC/DC on all ranges
DC Voltage
Range: 1000V
Resolution: 1V
Accuracy: ± 0.8% rdg +1d
Input Impedance: 9 MΩ
Overload Protection: 1000V DC/peak AC on all ranges
Resistance
Ranges: 200Ω/20KΩ
Resolution: 0.1Ω/10Ω
Accuracy: 200Ω ± 1% rdg +3d
20KΩ ± 1% rdg +1d
Overload Protection: 500V DC/rms AC on all ranges
Continuity Buzzer (200Ω range): 50Ω ±25Ω
Insulation Test
(using 500V insulation
tester, not included)
Ranges: 20MΩ/2000MΩ
Resolution: 10KΩ/1MΩ
Accuracy: 20MΩ ± 2% rdg +2d
2000MΩ ± 4% rdg +2d (up to 500MΩ)
2000MΩ ± 5% rdg +2d (above 500MΩ)
Operating Temperature Range: 32° - 122° F
Display
1
/
2
” high 3
1
/
2
-digit LCD
Reading Rate 3 readings/second
Measurement Method Dual slope integration
Overload Indicator
Most Signicant Digit*(MSD), decimal point and nega-
tive sign (if negative reading) shown alone
Battery One 9 V (included)
Weight 11 oz.
Accessories Test leads, battery, and carrying case
*Most Signicant digit is the digit farthest left.